Skip to content

Oven Device

  • Alerts


    A list of alerts this device can send to an application

    Go There

  • Service Alerts


    Alerts when things go wrong: faults occur

    Go There

  • Services


    A list of all the services this device might support.

    Go There

Tip: Use this navigation sections and page links to navigate easier.

Description

Oven appliance.

Label Value
Device Type cloud.smarthq.device.oven
Connection Type cloud.smarthq.connection.wifi
Icon Type cloud.smarthq.icon.oven

Alerts

AlertType
Description
Common Alerts List A list of alerts common across all SmartHQ devices that this device might support.

Service Alerts

AlertType
Description
cloud.smarthq.alert.fault.controller.clock.speed The MCU internal clock speed supervisor have a failure.
cloud.smarthq.alert.fault.coolingfan.cavity1.on The Range or Primary WO Cooling Fan unexpected a operation fault.
cloud.smarthq.alert.fault.coolingfan.cavity1.speed There is a range or primary WO Cooling Fan Speed Fault.
cloud.smarthq.alert.fault.coolingfan.cavity2.speed The secondary Cooling Fan Speed have a fault.
cloud.smarthq.alert.fault.cycle.cavity1.stillrunning The oven cavity 1 (or single) does not stop cooking within 500ms of pressing the cavity 1 (or single) cancel key.
cloud.smarthq.alert.fault.cycle.cavity2.stillrunning The oven cavity 2 (or single) does not stop cooking within 500ms of pressing the cavity 2 (or single) cancel key.
cloud.smarthq.alert.fault.doorlock.cavity1.failure The cavity 1 door lock failed to change to expected state.
cloud.smarthq.alert.fault.doorlock.cavity1.unexpected The cavity 1 door lock changed states unexpectedly.
cloud.smarthq.alert.fault.doorlock.cavity1.unknown The cavity 1 door lock is in an unknown state.
cloud.smarthq.alert.fault.doorlock.cavity2.failure The cavity 2 door lock failed to change to expected state.
cloud.smarthq.alert.fault.doorlock.cavity2.unexpected The cavity 2 door lock changed states unexpectedly.
cloud.smarthq.alert.fault.doorlock.cavity2.unknown The cavity 2 door lock is in an unknown state.
cloud.smarthq.alert.fault.doorswitch.cavity1.stuckopen The cavity 1 door detected as open when locked.
cloud.smarthq.alert.fault.doorswitch.cavity2.stuckopen The cavity 2 door detected as open when locked.
cloud.smarthq.alert.fault.element.runaway.cavity1.unlocked The Cavity 1 extended thermal runaway it's unlocked.
cloud.smarthq.alert.fault.heating.cavity1.malfunction The Cavity 1 heating element relay in unexpected state.
cloud.smarthq.alert.fault.heating.cavity2.malfunction The Cavity 2 heating element relay in unexpected state.
cloud.smarthq.alert.fault.key.cancel.error The cancel key scanning mismatch - OBC1 Only.
cloud.smarthq.alert.fault.key.cancel.keystuck Any RC17/RC19/OBC1/OBC2 cancel key is stuck for 30 seconds.
cloud.smarthq.alert.fault.key.warmingzone.cancel.error The Warming Zone starts without key sequence.
cloud.smarthq.alert.fault.key.warmingzone.cancel.keystuck The Cooktop it's stuck.
cloud.smarthq.alert.fault.keypress.selfclean.cavity1.start The Cavity 1 self clean started without 2 key inputs.
cloud.smarthq.alert.fault.keypress.selfclean.cavity2.start The Cavity 2 self clean started without 2 key inputs.
cloud.smarthq.alert.fault.keypress.warmingzone.start The Warming Zone started without 2 key inputs.
cloud.smarthq.alert.fault.keystuck If button is depressed for 1 minute, it will be logged as a stuck button.
cloud.smarthq.alert.fault.miswire.cavity1 Range or Primary WO Miswire detected after 10 mins.
cloud.smarthq.alert.fault.miswire.cavity2 Secondary WO Miswire detected within first 10 mins.
cloud.smarthq.alert.fault.powerloss.recovery There is a power loss recovery circuit failure.
cloud.smarthq.alert.fault.temperature.runaway.cavity1.locked The Cavity 1 Thermal Runaway it's Locked.
cloud.smarthq.alert.fault.temperature.runaway.cavity1.unlocked The Cavity 1 extended thermal runaway it's unlocked.
cloud.smarthq.alert.fault.temperature.runaway.cavity2.unlocked The Cavity 2 extended thermal runaway it's unlocked.
cloud.smarthq.alert.fault.thermistor.cavity1.analogdigital The range or primary WO Internal ADC diagnostic a failure.
cloud.smarthq.alert.fault.thermistor.cavity1.open The RTD1 sensor open-circuit detected (Lower/Single Cavity).
cloud.smarthq.alert.fault.thermistor.cavity1.short The RTD1 sensor short-circuit detected(Lower/Single Cavity).
cloud.smarthq.alert.fault.thermistor.cavity2.analogdigital The secondary WO Internal ADC diagnostic a failure.

Services

This device may not support each service listed. What is listed is all the possible services for this device. Learn more

Services
Description
Oven Sabbath Toggle Service Oven sabbath mode.
Common Services List A list of services common across all SmartHQ devices that this device might support.

Oven Sabbath Toggle Service

Description: Oven sabbath mode.

Tuple: Controls sabbath mode on an appliance

Attribute Value Description
ServiceType cloud.smarthq.service.toggle Service to model a binary state that can be read only or remotely controlled
DomainType cloud.smarthq.domain.sabbath The sabbath
ServiceDeviceType cloud.smarthq.device.appliance An appliance
Commands
Command Description
cloud.smarthq.command.toggle.set Toggle sabbath mode on the oven.