Oven Device¶
Tip: Use this navigation sections and page links to navigate easier.
Description¶
Oven appliance.
Label | Value |
---|---|
Device Type | cloud.smarthq.device.oven |
Connection Type | cloud.smarthq.connection.wifi |
Icon Type | cloud.smarthq.icon.oven |
Alerts¶
AlertType |
Description |
---|---|
Common Alerts List | A list of alerts common across all SmartHQ devices that this device might support. |
Service Alerts¶
AlertType |
Description |
---|---|
cloud.smarthq.alert.fault.controller.clock.speed |
The MCU internal clock speed supervisor have a failure. |
cloud.smarthq.alert.fault.coolingfan.cavity1.on |
The Range or Primary WO Cooling Fan unexpected a operation fault. |
cloud.smarthq.alert.fault.coolingfan.cavity1.speed |
There is a range or primary WO Cooling Fan Speed Fault. |
cloud.smarthq.alert.fault.coolingfan.cavity2.speed |
The secondary Cooling Fan Speed have a fault. |
cloud.smarthq.alert.fault.cycle.cavity1.stillrunning |
The oven cavity 1 (or single) does not stop cooking within 500ms of pressing the cavity 1 (or single) cancel key. |
cloud.smarthq.alert.fault.cycle.cavity2.stillrunning |
The oven cavity 2 (or single) does not stop cooking within 500ms of pressing the cavity 2 (or single) cancel key. |
cloud.smarthq.alert.fault.doorlock.cavity1.failure |
The cavity 1 door lock failed to change to expected state. |
cloud.smarthq.alert.fault.doorlock.cavity1.unexpected |
The cavity 1 door lock changed states unexpectedly. |
cloud.smarthq.alert.fault.doorlock.cavity1.unknown |
The cavity 1 door lock is in an unknown state. |
cloud.smarthq.alert.fault.doorlock.cavity2.failure |
The cavity 2 door lock failed to change to expected state. |
cloud.smarthq.alert.fault.doorlock.cavity2.unexpected |
The cavity 2 door lock changed states unexpectedly. |
cloud.smarthq.alert.fault.doorlock.cavity2.unknown |
The cavity 2 door lock is in an unknown state. |
cloud.smarthq.alert.fault.doorswitch.cavity1.stuckopen |
The cavity 1 door detected as open when locked. |
cloud.smarthq.alert.fault.doorswitch.cavity2.stuckopen |
The cavity 2 door detected as open when locked. |
cloud.smarthq.alert.fault.element.runaway.cavity1.unlocked |
The Cavity 1 extended thermal runaway it's unlocked. |
cloud.smarthq.alert.fault.heating.cavity1.malfunction |
The Cavity 1 heating element relay in unexpected state. |
cloud.smarthq.alert.fault.heating.cavity2.malfunction |
The Cavity 2 heating element relay in unexpected state. |
cloud.smarthq.alert.fault.key.cancel.error |
The cancel key scanning mismatch - OBC1 Only. |
cloud.smarthq.alert.fault.key.cancel.keystuck |
Any RC17/RC19/OBC1/OBC2 cancel key is stuck for 30 seconds. |
cloud.smarthq.alert.fault.key.warmingzone.cancel.error |
The Warming Zone starts without key sequence. |
cloud.smarthq.alert.fault.key.warmingzone.cancel.keystuck |
The Cooktop it's stuck. |
cloud.smarthq.alert.fault.keypress.selfclean.cavity1.start |
The Cavity 1 self clean started without 2 key inputs. |
cloud.smarthq.alert.fault.keypress.selfclean.cavity2.start |
The Cavity 2 self clean started without 2 key inputs. |
cloud.smarthq.alert.fault.keypress.warmingzone.start |
The Warming Zone started without 2 key inputs. |
cloud.smarthq.alert.fault.keystuck |
If button is depressed for 1 minute, it will be logged as a stuck button. |
cloud.smarthq.alert.fault.miswire.cavity1 |
Range or Primary WO Miswire detected after 10 mins. |
cloud.smarthq.alert.fault.miswire.cavity2 |
Secondary WO Miswire detected within first 10 mins. |
cloud.smarthq.alert.fault.powerloss.recovery |
There is a power loss recovery circuit failure. |
cloud.smarthq.alert.fault.temperature.runaway.cavity1.locked |
The Cavity 1 Thermal Runaway it's Locked. |
cloud.smarthq.alert.fault.temperature.runaway.cavity1.unlocked |
The Cavity 1 extended thermal runaway it's unlocked. |
cloud.smarthq.alert.fault.temperature.runaway.cavity2.unlocked |
The Cavity 2 extended thermal runaway it's unlocked. |
cloud.smarthq.alert.fault.thermistor.cavity1.analogdigital |
The range or primary WO Internal ADC diagnostic a failure. |
cloud.smarthq.alert.fault.thermistor.cavity1.open |
The RTD1 sensor open-circuit detected (Lower/Single Cavity). |
cloud.smarthq.alert.fault.thermistor.cavity1.short |
The RTD1 sensor short-circuit detected(Lower/Single Cavity). |
cloud.smarthq.alert.fault.thermistor.cavity2.analogdigital |
The secondary WO Internal ADC diagnostic a failure. |
Services¶
This device may not support each service listed. What is listed is all the possible services for this device. Learn more
Services |
Description |
---|---|
Oven Sabbath Toggle Service | Oven sabbath mode. |
Common Services List | A list of services common across all SmartHQ devices that this device might support. |
Oven Sabbath Toggle Service¶
Description: Oven sabbath mode.
Tuple: Controls sabbath mode on an appliance
Attribute | Value | Description |
---|---|---|
ServiceType | cloud.smarthq.service.toggle | Service to model a binary state that can be read only or remotely controlled |
DomainType | cloud.smarthq.domain.sabbath |
The sabbath |
ServiceDeviceType | cloud.smarthq.device.appliance |
An appliance |
Commands¶
Command | Description |
---|---|
cloud.smarthq.command.toggle.set | Toggle sabbath mode on the oven. |